Cycle Durability

  • Test Condition

Battery specification:
Environmental temperature: 25 degrees Celsius
Charge / discharge current rate: 2.0 C
Charge capacity ratio: 80%
Discharge cutoff condition: 0.8 V / cell

  • Test Condition

Battery specification: Single cell (200 Ah)
Environmental temperature: Normal temperature
SOC at start of test: 80%
Charge condition (in order): 400 A x 2 sec, 320 A x 2 sec, 240 A x 2 sec, 160 A x 2 sec, 80 A x 2 sec
Discharge condition (in order): 80 A x 2 sec, 160 A x 2 sec, 240 A x 2 sec, 320 A x 2 sec, 400 A x 2 sec
DOD: 0.33%

*SOC: State of Charge

*DOD: Depth of Discharge

GIGACELL is a trademark of Kawasaki Heavy Industries, Ltd. in Japan and the U.S.A.

Battery Energy Storage System

Contact

GIGACELL Battery Sales Section
Machinery & Parts Sales Department
Marketing & Sales Division
Rolling Stock Company
(Tokyo Head Office)
KAWASAKI HEAVY INDUSTRIES, LTD.